Use cases · Trip and downtime analysis

Know what led up to the stop.

After a trip, the answer is in the two hours before it. Beltr pulls every related tag, ranks what deviated from normal and puts the sequence on one screen.

For
Reliability engineer, Process engineer, Production manager
Beltr / Havgap Energi · Separator train A1 source · read-only● Agent ready
Compressor trip, Sunday
What happened before the export compressor tripped on Sunday?
  • Found the trip event and 14 related tags
  • Read 2 h before the trip · read-only · 3 queries
  • Ranked tags by deviation from the previous 30 days

Separator level 27-LT-1002.PV started to rise 45 min before the trip. Suction pressure then fell steadily while the anti-surge valve opened in steps, so the compressor was starved before it tripped.

QueriesTransformsInspect evidence
Ask a follow-up…
Train A · before the trip
  1. Deviation from the last 30 days
  2. 27-PT-1101.PVSuction pressure6.2 σ
  3. 27-ZT-1110.PVAnti-surge valve5.4 σ
  4. 27-LT-1002.PVSeparator level4.1 σ
  5. 27-TT-1105.PVDischarge temperature1.3 σ
  6. 27-VT-1120.PVShaft vibration0.6 σ
45 min before trip
27-PT-1101.PVSuction pressure
18.2 barg
27-LT-1002.PVSeparator level
71 %
Source: Process historian (ODBC)Synthetic demo siteInspect evidence →

Worked example from a fictive site with synthetic data.

The situation

Trip and downtime analysis, the way it usually goes.

The export compressor tripped on Sunday. The alarm list has four hundred entries from the minute it happened, and the first one is not necessarily the cause.

The useful picture is the slow change in the forty minutes before: which pressure fell, which valve opened, which level rose. It exists in the historian, spread over a dozen tags.

In Beltr

From question to answer in four steps.

The same example as in the window above, step by step.

01

Start from the event

“What happened before the export compressor tripped on Sunday?” Beltr finds the trip in the event data and the tags around the compressor.

02

The window before the event is read

Two hours before the trip, plus thirty normal days for reference, read-only and within the query limits you have set.

03

Tags are ranked by how far they left normal

Instead of four hundred alarms you get a short list: suction pressure, anti-surge valve position, separator level.

04

The sequence is laid out

Level rose first. Suction pressure fell for forty minutes while the anti-surge valve opened in steps. The compressor was starved before it tripped.

What you walk away with

An answer you can defend.

  • A timeline of the signals that moved, in the order they moved
  • The same analysis for every earlier trip, to see if the pattern repeats
  • Material for the incident report, with the queries attached
Questions about trip and downtime analysis

Good to know.

Does Beltr read the alarm and event system?
If events are stored in a database or exported to files Beltr can read, yes. Otherwise a trip can be found from a process signal, such as speed going to zero.
Can I look at all trips this year at once?
Yes. Ask for every stop of a unit in a period and Beltr aligns the window before each one, so repeating patterns stand out.
Will it ever send a command to the equipment?
Never. Beltr is read-only toward plant systems by construction and has no way to write a setpoint.
More use cases
Talk to Beltr

No commitment.